The condenser coils and the evaporator coils are the most crucial devices of HVAC units that have a reciprocating part in the heat exchanges. An evaporator coil vs. condenser coil is discovering the contrast in offerings,

Evaporator Coil Vs. Condenser Coil

As your condenser coil is the core working component for a system that needs attention, you can contact your local HVAC repair technician for all your performance and troubleshooting problems. Let’s take a look in to the specific diversity that differentiates these two major components in your HVAC system.

Evaporator Coil Vs. Condenser Coil: Functional Disparities

Therefore, we will first explain the evaporator coil and then proceed to briefly talk about its counterpart, the condenser coil. An AC evaporator coil manifests its capability of absorbing the external heat and humidity. In this case a condenser coil, instead, is aimed to discharge the previously captured heat from the indoor air to the outside area, so as to achieve the cooling process.

Disparities in Location

The evaporator coil is often inside the building; it could be housed along with the air handler or furnace of the HVAC system. It was installed on the interior, which put it close to the blower which pulls the warm air from the inside of the building through the ducts into the system. This ensures that the warmed air should circulate within the room and be driven via the coil where it is cooled and dehumidified.

As opposed to this, on the outdoors, the condenser coil is usually found on the exterior pressurized box of all the split AC systems. In other words, it can release heat to the open air, and this way is basically critical for cooling procedures. The outdoor installation of the condenser coil is another externality of this approach as it avoids the development hot air under the indoor end-user living area.

Evaporator Coil Vs. Condenser Coil

Variations in Design

The evaporator coil absorbs the indoor air incredible towards heat by having the refrigerant evaporate to the low pressure gas states and absorbs the heat into it when the air passes via. As a result of this heat absorption, the cooling effect is brought to the sustainable living space through circulation of such cooler air.

Furthermore, the evaporator coil performs dehumidification as it condenses heat from the air onto its surface, which is caused when the refrigerant evaporates. With this, the indoor area becomes a cool and comfortable a place.

The evaporator coil receives hot and highly pressurized refrigerant gas from a compressor Condenser’s coil is filled with refrigerant which gets transformed from gas into a liquid as heat is being released into the surrounding outdoor air.

Rather than stay in the evaporator as a gas, with too high of pressure, the refrigerant can now change to the liquid state and goes back to the evaporator as part of the cooling process.

Differences in the Maintenance:

It’s fundamental to clean the evaporator coil and the condenser coil of your heating, ventilation and air conditioning (HVAC) system to ensure efficient operation and avoid breakdowns, as well as the equipment malfunctioning. It is a walk-through process of what you can do during your free time to clean the AC coil yourself or you can pay a professional to come to your place and clean the coils for you.

The evaporator coils must be cleaned regularly to avoid problems from packets flow blocked and the cooling reduced. An example is a dirty evaporator coil may cause the system to freeze and hence needs to be cleaned frequently. In other hand, deeper cleaning of outdoor condensers should be done regularly not once or twice a year, because of the exposure to the outdoor elements, and more chance of dirt a debris collection.

Evaporator Coil Vs. Condenser Coil

Cost Differences:

Condenser coils are usually longer and wider to contain a larger quantity of refrigerant, hence making them the pricier option. If a condenser coil needs to be replaced, it most likely will cost you from $550 to $1,100, while for a replacement a condenser coil you will pay anywhere from $900 to $2,800.

Frequently Asked Question

Although you will keep the AC operating by replacing only the evaporator coil, it’s also true that you might have to deal with other problems in the future. A working principle of an AC system is the whereas a condenser and evaporator coils are equally important. Substituting only one coil in older models is not rare. It may interrupt the harmony and even cause the breakdown of a HVAC system.

Investing in a new air-conditioner versus incurring the cost for pricey repairs or replacements of individual units are typically better than bearing the costs of the maintenance of the entire AC system at the end to avoid costly repairs.

Indeed, Evaporator Coil Vs. Condenser Coil can be unmatched in the AC system, which cause severe damage. An example of this is a situation where the system has to be working for longer in order to achieve the same goals as it would have when natural energy was not obstructed. Too frequent season switching may also produce such virtual overload, which is a serious problem for the efficiency of the power grid and its life span.

Additionally, tripped breakers can cause higher temperatures and humidity levels indoors. On top of all, making a changed coil by itself may hurt the warranty since those parts are used to work in a group and when you use different sizes of coils this could result in repairs or even system breakdown.